Marine casualties and vessel inspections
Closed Coast Guard investigations of marine casualties (groundings, collisions, fires, spills, deaths and injuries on the water) since 2002, and Coast Guard vessel inspections since 2010 with each deficiency found and each time a ship was held or restricted.
- Published by
- U.S. Coast Guard (MISLE, via CGMIX)
- Finest detail
- point
- Tables
- 4
- One row is
- one investigation; one inspection activity; one deficiency; one operational control
- Key columns
- activity_id, misle_vessel_id, imo_number, u_s_official_number
- Good to know
- Casualty rows are closed investigations only, so recent cases appear once the Coast Guard closes them. Some dates in the inspection files are placeholders from the source (for example 1778).
- Source
- https://cgmix.uscg.mil/
Check the real rows
These rows come straight from our refreshed copy of the U.S. Coast Guard (MISLE, via CGMIX) file, so you can see exactly what you would be working with before you pay.
Deficiencies found
Sample of 25 rows out of about 346,115
· 16 columns
Swipe sideways to see all columns.
| id | activity_id | misle_vessel_id | deficiency_id | deficiency_code | system | subsystem | component | issued_date | due_date | resolved_date | condition | action | action_code | deficieny_description | resolution_description |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 3532727 | 667071 | 1635272 | No data | Fire Fighting | Structural Fire Protection - General | Fiber Reinforced Plastic | 2009-11-15 00:00:00 | 2010-01-20 00:00:00 | 2010-01-20 00:00:00 | Improper Installation | 705 - Other - as specified | a - To the satisfaction of RO/RSO | Renew deck grating which provides access to the foam monitors on the cargo deck with an approved type | Item was issued as a condition of class. |
| 2 | 3541313 | 51995 | 1630864 | No data | Documentation | Certificates/Documents | Certificate of Financial Responsibility | 2010-01-12 00:00:00 | No data | 2010-10-13 00:00:00 | No data | 701 - Prior to carriage of passengers/cargo | c - To the satisfaction of the Coast Guard | Provide proof of vessel's COFR | Found correct |
| 3 | 3541313 | 51995 | 1630868 | No data | Documentation | Safety/Response Plans/Programs | Vessel Response Plan | 2010-01-12 00:00:00 | No data | 2010-10-13 00:00:00 | No data | 701 - Prior to carriage of passengers/cargo | c - To the satisfaction of the Coast Guard | Provide an approved Vessel Response Plan. | No data |
| 4 | 3609743 | 270125 | 1629820 | No data | Electrical | Electric Generation Source (service) | Generator | 2009-12-21 00:00:00 | 2010-03-06 00:00:00 | 2010-02-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Provide a single line electrical diagram and generator specs for newly installed generator, Submit to USCG Sector LA-LB for approval. | Provided diagram of Generator. |
| 5 | 3609743 | 270125 | 1636348 | No data | Electrical | Electrical Distribution System (service) | Junction Box | 2010-01-06 00:00:00 | 2010-02-06 00:00:00 | 2010-02-05 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Replace J-Box cover for hydrualic pump motor in fuel tank compartments and secure wire nuts. | J-Box cover installed and wire nuts secured. |
| 6 | 3615055 | 155280 | 1621251 | No data | Fire Fighting | Fire Pumps | Pressure | 2009-11-05 00:00:00 | No data | 2010-03-26 00:00:00 | No data | 701 - Prior to carriage of passengers/cargo | c - To the satisfaction of the Coast Guard | Prove operation of main fire pump to meet 46CFR 181.300. | No data |
| 7 | 3615055 | 155280 | 1621252 | No data | Engineering | Pressure Vessel | Shell Plate | 2009-11-05 00:00:00 | No data | 2009-11-05 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Provide size of pressure vsl IAW 46CFR176.812 | Operator able to compute size of pressure vessel to be 3.95 cubic feet. size of tank is 34 inches by 16 inches. |
| 8 | 3615055 | 155280 | 1621253 | No data | Communications | Radio Communications | VHF Radiotelephone | 2009-11-05 00:00:00 | No data | 2009-11-05 00:00:00 | No data | 705 - Other - as specified | b - To the satisfaction of the Administration | Install call sign near radio IAW 46CFR184.506 | Operator installed call sign on Emergency placard. |
| 9 | 3615055 | 155280 | 1621254 | No data | Lifesaving | Lifebuoys | Serviceable | 2009-11-05 00:00:00 | No data | 2010-02-24 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Install retro tape on both sides of ring buoys iaw 46CFR185.604 | No data |
| 10 | 3615055 | 155280 | 1621255 | No data | Accommodation/Occupational Safety | Other Accommodation Spaces | Recreation Space | 2009-11-05 00:00:00 | No data | 2010-02-22 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Repair storage door in lavatory to be able to close properly. | Electrical wire to the freezer was ran through the door jam on the hinge side preventing the door from properly closing. Wire was relocated allowing the door to properly close. |
| 11 | 3615055 | 155280 | 1621256 | No data | Pollution Prevention/Response | Prevention Equipment | Bilge Monitor | 2009-11-05 00:00:00 | No data | 2010-02-24 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Clean bilges in engine copartment IAW 46CFR176.830 | No data |
| 12 | 3615055 | 155280 | 1621257 | No data | Engineering | Diesel Engine (propulsion-direct drive) | Cylinder Head | 2009-11-05 00:00:00 | No data | 2010-02-22 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Clean oil off port engine near supercharger. | Oil was wiped up, engine was ran with no evidence of an oil leak. It''s believed oil was from recent maintenance. |
| 13 | 3615055 | 155280 | 1621258 | No data | Accommodation/Occupational Safety | Occupational Safety | Tripping/Falling Hazard | 2009-11-05 00:00:00 | No data | 2010-02-22 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Remove items and clear path for Emergency escape in forward compartment lower deck. | Items were removed clearing the emergency exit path. |
| 14 | 3620588 | 47660 | 1630552 | No data | Electrical | Electric Supply System (service) | Overcurrent Device | 2010-01-07 00:00:00 | 2010-01-21 00:00:00 | 2010-02-18 00:00:00 | Unknown | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Contactor cover for anchor capstain is missing. Located in forward compartment. | No data |
| 15 | 3620588 | 47660 | 1630553 | No data | Electrical | Lighting (service) | Lighting Fixture | 2010-01-07 00:00:00 | 2010-01-12 00:00:00 | 2010-01-15 00:00:00 | Unknown | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Broken light fixture on aft stbd bulkhead in fuel tank space. | Fixture was removed. |
| 16 | 3620588 | 47660 | 1630562 | No data | Fire Fighting | Fixed CO2 Fire Extinguishing System | Operating Controls | 2010-01-07 00:00:00 | 2010-01-15 00:00:00 | 2010-01-15 00:00:00 | No data | 705 - Other - as specified | b - To the satisfaction of the Administration | In accordance with 46 CFT 181.400 & 181.410, vessel must provide a fixed fire extinguishing system for aft generator compartment. Plans for system must be provided to USCG Sector LA/LB prior to installation. | Installed new SEA-FIRE system. System was tested on 15JAN2010. |
| 17 | 3620588 | 47660 | 1632279 | No data | Engineering | Fuel Oil Storage/Transfer System | Tank | 2010-01-07 00:00:00 | 2010-01-30 00:00:00 | 2010-02-18 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Fuel leaking from port forward fuel tank. | No data |
| 18 | 3620588 | 47660 | 1632282 | No data | Construction/Loadline | Structures | Longitudinal Bulkhead | 2010-01-07 00:00:00 | 2010-01-30 00:00:00 | 2010-02-18 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Clean Rot to good wood on overhead forward bulkhead and at entrace to engine room space. Treat areas. | No data |
| 19 | 3626419 | 45476 | 1638282 | No data | Engineering | Sea-water System (primary cooling) | Valve | 2010-02-10 00:00:00 | No data | 2010-03-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Make all valves ready for inspection. | All valves were ready for inspection. |
| 20 | 3626419 | 45476 | 1638283 | No data | Construction/Loadline | Hull | Hull Plating | 2010-02-10 00:00:00 | No data | 2010-03-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Clean side shell plate, starboard side of mid body compartment in way of severe pitting and delamination. | Cleaned side shell plate in way of pitting. |
| 21 | 3626419 | 45476 | 1638284 | No data | Construction/Loadline | Hull | Girder | 2010-02-10 00:00:00 | No data | 2010-03-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Crop and renew the deteriorated area of top flange on outboard girder port side in mid body compartment. | Cropped and renewed deteriorated area of top flange on outboard girder. |
| 22 | 3626419 | 45476 | 1638285 | No data | Construction/Loadline | Hull | Side Shell | 2010-02-10 00:00:00 | No data | 2010-03-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Crop and renew delaminated hull plate in mid body compartment forward of fuel tank. | Cropped and renewed delaminated hull plate forward of fuel tank. |
| 23 | 3626419 | 45476 | 1638286 | No data | Stability | Watertight Integrity | Coaming | 2010-02-10 00:00:00 | No data | 2010-03-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Replace broken hatch and coaming leading into engine room. | Replaced broken hatch an coaming leading into engine room. |
| 24 | 3626419 | 45476 | 1638287 | No data | Engineering | Fuel Oil Storage/Transfer System | Piping | 2010-02-10 00:00:00 | No data | 2010-03-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Prove integrity of rusted and deteriorated fuel piping or replace. | Replaced rusted fuel piping. |
| 25 | 3626419 | 45476 | 1638288 | No data | Construction/Loadline | Hull | Longitudinal Frame | 2010-02-10 00:00:00 | No data | 2010-03-08 00:00:00 | No data | 705 - Other - as specified | c - To the satisfaction of the Coast Guard | Crop and renew 1st and second side longitudinal frames just forward of aft engine room bulkhead. | Cropped and renewed 1st and 2nd side longs fwd of aft engine room bulkhead. |
Need the whole file? Spreadsheet links, downloads, and AI access come with Level 3 on any desk that covers this source. Try it free for 7 days.
See pricingSource data published by U.S. Coast Guard (MISLE, via CGMIX). Data Doughnut shows it as published; US states + DC.