Data Doughnut
Data catalog › Community health & safety

U.S. DOT PHMSA

Pipeline incidents

Every incident pipeline operators reported since 1970 — gas distribution, gas transmission and gathering, hazardous liquid, and LNG: when, where, operator, cause, deaths, injuries, and cost. All the old and new report forms read into one table, with each original report kept whole.

Published by U.S. DOT PHMSA Finest detail point Tables 1
How we use this · on 2 desks

“Have pipelines had incidents near here?”

Where you'll see it

What we added

  • Fifty years of reports on different government forms read into one table
  • Each incident placed in its county

See the desks →

Pipeline incident reports Sample of 25 rows out of about 70,552 · 20 columns
report_numberpipeline_systemyearlocal_dtoperatoroperator_idstatecountycitylatlondeathsinjuriestotal_costcausecommodityignitedexplodedfile_dateraw
20210003Hazardous liquid (gravity / reporting-regulated)20212021-01-04 11:50:00CENTURION PIPELINE L.P.31888TXGARZANOT WITHIN MUNICIPALITY33.38734-101.443240027818.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/3/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210003", "SUPPLEMENTAL_NUMBER": "34974", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "31888", "NAME": "CENTURION PIPELINE L.P.", "OPERATOR_STREET_ADDRESS": "1300 MAIN STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "1/4/2021 11:50", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "33.38734", "LOCATION_LONGITUDE": "-101.44324", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "20", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "15", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "AIR PATROL", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "CONTRACTOR WORKING FOR THE OPERATOR", "INCIDENT_IDENTIFIED_DATETIME": "1/4/2021 11:50", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/4/2021 12:50", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "NOT WITHIN MUNICIPALITY", "ONSHORE_COUNTY_NAME": "GARZA", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "3", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "8.3", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "80", "EST_COST_GAS_RELEASED": "238", "EST_COST_PROP_DAMAGE": "15000", "EST_COST_EMERGENCY": "2500", "EST_COST_ENVIRONMENTAL": "10000", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "REPLACEMENT PIPE FABRICATED, SCHEDULED FOR HYDRO, AND INSTALLATION SCHEDULED.", "PRPTY": "27818", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "EXTERNAL CORROSION", "PREPARER_NAME": "JOSHUA MCCULLOCH", "PREPARER_TITLE": "PROJECT ENGINEER", "PREPARER_EMAIL": "joshua_mcculloch@centurionpl.com", "PREPARER_TELEPHONE": "346-803-2869", "PREPARER_FAX": "713-215-7455", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON JANUARY 4, 2021, AT APPROXIMATELY 11:50 CST, AN AIR PATROL PILOT DISCOVERED A POSSIBLE LEAK ON THE FORBES TO SOUTHLAND 3'' NON-REGULATED GATHERING LINE NEAR POST, TEXAS IN GARZA COUNTY, TEXAS. THE AIR PATROL PILOT NOTIFIED CENTURION PIPELINE L.P. (CPL), AND CPL IMMEDIATELY DISPATCHED A COMPANY EMPLOYEE TO THE LOCATION. ON JANUARY 4, 2021, AT APPROXIMATELY 12:50 CST, CPL RESOURCES ARRIVED ON-SITE AND DETERMINED THE SOURCE OF THE LEAK TO BE THE FORBES TO SOUTHLAND 3'' PIPELINE. CPL PROMPTLY ISOLATED THE LEAK AND BEGAN CLEAN UP EFFORTS. HOWEVER, 20 BARRELS OF CRUDE OIL WERE RELEASED. CPL RECOVERED 15 BARRELS OF CRUDE OIL IN LIQUID FORM AND REMEDIATED THE CONTAMINATED SOIL ON SITE. NO INJURIES, FATALITIES, OR FIRES WERE ASSOCIATED WITH THIS INCIDENT. AT THE TIME OF THIS WRITING, THE PERMANENT REPAIR OF THE PIPELINE SEGMENT IS SCHEDULED AND THE ROOT CAUSE FAILURE ANALYSIS WILL BE CONDUCTED PENDING THE REMOVAL OF THE DAMAGED PIPE. THE REPLACEMENT PIPE HAS BEEN FABRICATED, SCHEDULED FOR HYDRO, AND INSTALLATION SCHEDULED FOR THE 2ND WEEK OF FEBRUARY. THE RESULTING INFORMATION RELATED TO THE CAUSE OF THE LEAK AND COSTS ASSOCIATED WITH REPAIRING THE PIPELINE WILL BE SUBMITTED VIA SUPPLEMENTAL REPORT(S). SUPPLEMENTAL FILED ON 03/10/2021: UPDATED PART A4, D6A, AND D6C. DURING THE ROOT CAUSE ANALYSIS, CPL IDENTIFIED THE LEAK AS EXTERNAL CORROSION CAUSED BY DISBONDED COATING WHICH SHIELDED THE PIPELINE FROM CATHODIC PROTECTION AND ALLOWED A CORROSION CELL TO FORM. UPON EXCAVATION, CPL DISCOVERED THE POORLY ADHERED COAL TAR COATING, CAUSED BY AGE AND SOIL STRESS, EXTENDED BEYOND THE IMMEDIATE LEAK LOCATION. CPL REPLACED 700 FEET OF PIPE AFFECTED BY THE DISBONDED COATING AND BELIEVES THE PIPE REPLACEMENT WILL PREVENT THE OCCURRENCE OF SIMILAR ACCIDENTS."}
20210004Hazardous liquid (gravity / reporting-regulated)20212021-01-11 10:56:00BELLE FOURCHE PIPELINE CO1248NDMCKENZIE COUNTYWATFORD CITY47.6013-103.5009580035261.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/4/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210004", "SUPPLEMENTAL_NUMBER": "35194", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "1248", "NAME": "BELLE FOURCHE PIPELINE CO", "OPERATOR_STREET_ADDRESS": "455 N POPLAR ST.", "OPERATOR_CITY_NAME": "CASPER", "OPERATOR_STATE_ABBREVIATION": "WY", "OPERATOR_POSTAL_CODE": "82602", "LOCAL_DATETIME": "1/11/2021 10:56", "TIME_ZONE": "MOUNTAIN", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "47.6013", "LOCATION_LONGITUDE": "-103.500958", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "5", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "5", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "AIR PATROL", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "CONTRACTOR WORKING FOR THE OPERATOR", "INCIDENT_IDENTIFIED_DATETIME": "1/11/2021 10:56", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/11/2021 12:45", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "ND", "ONSHORE_CITY_NAME": "WATFORD CITY", "ONSHORE_COUNTY_NAME": "MCKENZIE COUNTY", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "6", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "2.05", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "261", "EST_COST_PROP_DAMAGE": "500", "EST_COST_EMERGENCY": "34500", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "35261", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "INTERNAL CORROSION", "PREPARER_NAME": "KEVIN PENA", "PREPARER_TITLE": "PIPELINE COMPLIANCE COORDINATOR", "PREPARER_EMAIL": "kevin.pena@truecos.com", "PREPARER_TELEPHONE": "4066873304", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ROUTINE AIR PATROL CALLED IN THE LEAK ON THE MORNING OF 01/11/2021 AT 10:56 AM MST, INCLUDING APPROXIMATE LATITUDE/LONGITUDE COORDINATES. UPON REPORT OF THE LEAK, CONTACT WAS MADE WITH THE PUMPER, WHO WAS ABLE TO SHUT THE LINE DOWN BY 11:15 AM. LOCAL COMPANY RESPONSE PERSONNEL ARRIVED AT APPROXIMATELY 12:45 PM ON THE SAME DAY. FOLLOWING CONFIRMATION OF THE LINE ISOLATION, THE LINE WAS EXPOSED AND CLAMPED OVERNIGHT. REPAIR OF THE LINE WAS COMPLETED USING PRE-TESTED PIPE ON 01/12/2021, AND THE LINE WAS RESTARTED AT APPROXIMATELY 4:00 PM ON THE AFTERNOON OF 01/13/2021. THERE ARE NO CHANGES OR ADDITIONAL INFORMATION INCLUDED IN THE SUPPLEMENTAL REPORT. THE ORIGINAL SUBMITTAL SHOULD HAVE ALSO BEEN CHECKED AS \"FINAL,\" BUT THAT SELECTION WAS INADVERTENTLY MISSED DURING THE INITIAL SUBMISSION."}
20210005Hazardous liquid (gravity / reporting-regulated)20212021-01-21 12:45:00ENERGY TRANSFER COMPANY32099NMLEAJAL32.3115885-103.63778330040300.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/9/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210005", "SUPPLEMENTAL_NUMBER": "34830", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "32099", "NAME": "ENERGY TRANSFER COMPANY", "OPERATOR_STREET_ADDRESS": "1300 MAIN STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "1/21/2021 12:45", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.3115885", "LOCATION_LONGITUDE": "-103.6377833", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "3.6", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "3.6", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "1/21/2021 11:59", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/21/2021 14:08", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "NM", "ONSHORE_CITY_NAME": "JAL", "ONSHORE_COUNTY_NAME": "LEA", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "6.625", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "4", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "300", "EST_COST_PROP_DAMAGE": "25000", "EST_COST_EMERGENCY": "0", "EST_COST_ENVIRONMENTAL": "15000", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "40300", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "INTERNAL CORROSION", "PREPARER_NAME": "CHRISTOPHER PALAFOX", "PREPARER_TITLE": "SPECIALIST REGULATORY COMPLIANCE", "PREPARER_EMAIL": "christopher.palafox@energytransfer.com", "PREPARER_TELEPHONE": "713-989-4464", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON JANUARY 21, 2021 AT APPROXIMATELY 11:59 NEAR THE CUERVO LACT UNIT, A FIELD TECHNICIAN DISCOVERED A SPILL DURING HIS DAILY ROUNDS AND NOTIFIED OPERATIONS. OPERATIONS NOTIFIED THE CONTROL CENTER TO SHUT DOWN THE SHURVESA LACT UNITS. IT WAS CONFIRMED AT 12:45 THAT THE CRUDE OIL SPILL CAME FROM THE CG126 CIMAREX NM D9 ON THE SHURVESA GATHERING SYSTEM. THE LEAK WAS DUE INTERNAL CORROSION AT THE 6 O'CLOCK POSITION ON THE PIPE BODY. THE LEAK WAS ISOLATED BY DOWNSTREAM BLOCK VALVES AND A SKILLET BLIND FLANGE WAS INSTALLED TO ISOLATE FROM GATHERING SYSTEM. A PLIDCO CLAMP WAS INSTALLED ON THE AFFECTED SECTION OF PIPE. A THIRD-PARTY COMPANY WAS CALLED TO CLEAN UP ALL THE FREE PRODUCT AND REMEDIATE THE SOIL. AT 19:00 THE CONTROL CENTER RESTARTED THE SHURVESA SYSTEM. THE CG126 CIMAREX NM D9 WILL REMAIN OUT OF SERVICE AND ISOLATED FROM THE SHURVESA SYSTEM UNTIL A DETERMINATION FOR BEST PERMANENT REPAIR. TO PREVENT FURTHER SPILLS FROM THIS LINE, INSPECTIONS ARE BEING CONDUCTED ON THE AFFECTED SECTION AND ADDITIONAL 40 FEET ON EACH SIDE FOR ADDITIONAL ANOMALIES AND A HYDRO FORM SCAN WILL BE CONDUCTED TO DETERMINE THE BEST PERMANENT REPAIR."}
20210006Hazardous liquid (gravity / reporting-regulated)20212021-01-26 11:38:00ENERGY TRANSFER COMPANY32099NMLEAJAL32.20703-103.4526120045250.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/9/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210006", "SUPPLEMENTAL_NUMBER": "34831", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "32099", "NAME": "ENERGY TRANSFER COMPANY", "OPERATOR_STREET_ADDRESS": "1300 MAIN STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "1/26/2021 11:38", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.20703", "LOCATION_LONGITUDE": "-103.452612", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "3", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "3", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "1/26/2021 11:20", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/26/2021 11:45", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "NM", "ONSHORE_CITY_NAME": "JAL", "ONSHORE_COUNTY_NAME": "LEA", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "8.625", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "2", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "250", "EST_COST_PROP_DAMAGE": "25000", "EST_COST_EMERGENCY": "0", "EST_COST_ENVIRONMENTAL": "20000", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "45250", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "INTERNAL CORROSION", "PREPARER_NAME": "CHRISTOPHER PALAFOX", "PREPARER_TITLE": "SPECIALIST REGULATORY COMPLIANCE", "PREPARER_EMAIL": "christopher.palafox@energytransfer.com", "PREPARER_TELEPHONE": "7139894464", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON JANUARY 26, 2021 AT APPROXIMATELY 11:20 AT THE LEA STATION, A COMPANY EMPLOYEE NOTICED A RELEASE DURING HIS DAILY CHECKS. AT 11:38 THE SPILL WAS CONFIRMED THAT CRUDE OIL WAS LEAKING FROM THE CG105 CIMAREX TRUNKLINE 8 INCH (NON-REGULATED GATHERING LINE) ON THE SHURVESA GATHERING SYSTEM. THE CONTROL CENTER SHUT DOWN ALL LACT UNITS ON THE SHURVESA SYSTEM. A THIRD PARTY WAS CALLED IN TO PICK UP ALL FREE PRODUCT AND THE SOIL WAS REMEDIATED. IT WAS DETERMINED THAT INTERNAL CORROSION CAUSED THE LEAK AT THE 5:30 POSITION ON THE PIPE BODY. A PLIDCO CLAMP WAS INSTALLED ON THE AFFECTED PORTION OF THE PIPE. TO PREVENT FUTURE SPILLS, SAMPLING OF THE PRODUCT, INCREASE PIG RUNS AND ADDING ADDITIONAL CORROSION MONITORING WILL BE IMPLEMENTED. ON JANUARY 27, 2021 AT APPROXIMATELY 18:31 THE CONTROL CENTER STARTED THE LINE BACK UP AND BRING THE LACT UNITS BACK ONLINE SLOWLY. THE PLIDCO CLAMP WAS MONITORED THROUGH THE NIGHT TO ENSURE INTEGRITY OF THE CLAMP."}
20210007Hazardous liquid (gravity / reporting-regulated)20212021-01-14 11:00:00ENTERPRISE CRUDE PIPELINE LLC30829NMLEAN/A32.1986-103.5491009506.0INCORRECT OPERATIONCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/12/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210007", "SUPPLEMENTAL_NUMBER": "34950", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "30829", "NAME": "ENTERPRISE CRUDE PIPELINE LLC", "OPERATOR_STREET_ADDRESS": "1100 LOUISIANA STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "1/14/2021 11:00", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.1986", "LOCATION_LONGITUDE": "-103.5491", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "0.12", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "0.12", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "1/14/2021 11:00", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/14/2021 11:00", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "YES", "OSRO_OPERATOR_NOTIFIED_DT": "1/14/2021 11:52", "OSRO_ARRIVED_ON_SITE_DT": "1/14/2021 13:30", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "NM", "ONSHORE_CITY_NAME": "N/A", "ONSHORE_COUNTY_NAME": "LEA", "FEDERAL": "YES", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "VALVE", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "0.04", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "6", "EST_COST_PROP_DAMAGE": "4000", "EST_COST_EMERGENCY": "5500", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "9506", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "INCORRECT OPERATION", "CAUSE_DETAILS": "OTHER INCORRECT OPERATION", "PREPARER_NAME": "YAROSLAV BIL", "PREPARER_TITLE": "PIPELINE COMPLIANCE ENGINEER", "PREPARER_EMAIL": "ybil@eprod.com", "PREPARER_TELEPHONE": "713-381-5650", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "YAROSLAV BIL", "LOCAL_CONTACT_EMAIL": "ybil@eprod.com", "LOCAL_CONTACT_TELEPHONE": "713-381-5650", "NARRATIVE": "ON 01/14/2021 AT 11:00 AM, A CONTRACTOR WAS AT THE BLUE KRAIT LACT SKID PERFORMING MAINTENANCE ON A VALVE ACTUATOR. UPON REMOVAL OF THE VALVE STEM PACKING GLAND, THE PACKING EXPELLED FROM THE VALVE, CAUSING A SPRAY OF CRUDE OIL. IT WAS DETERMINED THAT THE 3RD PARTY VALVE TECHNICIAN MAY NOT HAVE REFERENCED THE MANUFACTURER'S IOM (INSTALLATION, OPERATION, MAINTENANCE) MANUAL AND MISUNDERSTOOD THE DESIGN OF THE VALVE'S DESIGN BEING WORKED ON. THE IOM CONTAINED A WARNING STATEMENT TO NOT REMOVE THE PACKING GLAND WHILE THE LINE IS UNDER PRESSURE. THE LINE HAD APPROXIMATELY 95 PSIG OF PRESSURE AT THE TIME OF RELEASE. THE LEAK WAS IMMEDIATELY ISOLATED AND CLEANED UP. THE VALVE WAS REPAIRED AND THE SYSTEM WAS RETURNED TO SERVICE. ALL SOIL WAS REMEDIATED. NO FREE LIQUID AVAILABLE FOR RECOVERY."}
20210008Hazardous liquid (gravity / reporting-regulated)20212021-01-22 15:58:00CENTURION PIPELINE L.P.31888TXANDREWSNOT WITHIN MUNICIPALITY32.29922-102.576450010070.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/18/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210008", "SUPPLEMENTAL_NUMBER": "34877", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "31888", "NAME": "CENTURION PIPELINE L.P.", "OPERATOR_STREET_ADDRESS": "1300 MAIN STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "1/22/2021 15:58", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.29922", "LOCATION_LONGITUDE": "-102.57645", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "3", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "3", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "THIRD PARTY OPERATOR PERSONNEL", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "1/22/2021 15:04", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/22/2021 15:58", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "NOT WITHIN MUNICIPALITY", "ONSHORE_COUNTY_NAME": "ANDREWS", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "4", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "0.01", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "31", "EST_COST_GAS_RELEASED": "157", "EST_COST_PROP_DAMAGE": "6506", "EST_COST_EMERGENCY": "1750", "EST_COST_ENVIRONMENTAL": "1626", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "10070", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "INTERNAL CORROSION", "PREPARER_NAME": "JOSHUA MCCULLOCH", "PREPARER_TITLE": "PROJECT ENGINEER", "PREPARER_EMAIL": "joshua_mcculloch@centurionpl.com", "PREPARER_TELEPHONE": "346-803-2869", "PREPARER_FAX": "713-215-7455", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON JANUARY 22, 2021, AT APPROXIMATELY 15:04 CST, A THIRD PARTY OPERATOR EMPLOYEE DISCOVERED A POSSIBLE LEAK ON THE JAKE HAMON PARKER 4\" NON-REGULATED GATHERING LINE NEAR ANDREWS, TEXAS IN ANDREWS COUNTY, TEXAS. THE THIRD PARTY OPERATOR EMPLOYEE NOTIFIED CENTURION PIPELINE L.P. (CPL), AND CPL IMMEDIATELY DISPATCHED A COMPANY EMPLOYEE TO THE LOCATION. ON JANUARY 22, 2021, AT APPROXIMATELY 15:58 CST, CPL RESOURCES ARRIVED ON-SITE AND DETERMINED THE SOURCE OF THE LEAK TO BE THE JAKE HAMON PARKER 4\" PIPELINE. CPL PROMPTLY ISOLATED THE LEAK AND BEGAN CLEAN UP EFFORTS. HOWEVER, 3 BARRELS OF CRUDE OIL WERE RELEASED. CPL REMOVED THE CONTAMINATED SOIL AND PERFORMED THE REMEDIATION OFF SITE. NO INJURIES, FATALITIES, OR FIRES WERE ASSOCIATED WITH THIS INCIDENT. DURING THE ROOT CAUSE FAILURE ANALYSIS, CPL DETERMINED THE CAUSE OF LEAK TO BE INTERNAL CORROSION DUE TO LIMITED FLOW. AS A RESULT, CPL WILL EVALUATE THE POTENTIAL FOR PURGING AND IDLING THIS PIPELINE. CPL BELIEVES IDLING THIS PIPELINE DUE TO LIMITED FLOW WILL PREVENT SIMILAR LEAKS IN THE FUTURE."}
20210009Hazardous liquid (gravity / reporting-regulated)20212021-01-21 10:45:00PLAINS PIPELINE, L.P.300NMEDDYHOBBS32.594895-103.55068500113210.0MATERIAL FAILURE OF PIPE OR WELDCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/19/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210009", "SUPPLEMENTAL_NUMBER": "35254", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "300", "NAME": "PLAINS PIPELINE, L.P.", "OPERATOR_STREET_ADDRESS": "333 CLAY STREET, SUITE 1900", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "1/21/2021 10:45", "TIME_ZONE": "MOUNTAIN", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.594895", "LOCATION_LONGITUDE": "-103.550685", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "8", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "8", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "NOTIFICATION FROM THIRD PARTY", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "1/21/2021 11:00", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/21/2021 11:00", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "NM", "ONSHORE_CITY_NAME": "HOBBS", "ONSHORE_COUNTY_NAME": "EDDY", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "JOINT, INCLUDING HEAT-AFFECTED ZONE", "PIPE_TYPE": "", "JOINT_SUBTYPE": "OTHER BUTT JOINT", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "MATERIAL OTHER THAN CARBON STEEL", "MATERIAL_DETAILS": "POLYETHYLENE PIPE", "PERCENT_PIPE_SMYS": "", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "210", "EST_COST_PROP_DAMAGE": "5000", "EST_COST_EMERGENCY": "48000", "EST_COST_ENVIRONMENTAL": "60000", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "113210", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "MATERIAL FAILURE OF PIPE OR WELD", "CAUSE_DETAILS": "DESIGN-, CONSTRUCTION-, INSTALLATION-, OR FABRICATION-RELATED", "PREPARER_NAME": "NICOLAS GONZALEZ", "PREPARER_TITLE": "HSE COMPLIANCE SPECIALIST", "PREPARER_EMAIL": "nagonzalez@paalp.com", "PREPARER_TELEPHONE": "7136464376", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "NICOLAS GONZALEZ", "LOCAL_CONTACT_EMAIL": "nagonzalez@paalp.com", "LOCAL_CONTACT_TELEPHONE": "7136464376", "NARRATIVE": "APPROXIMATELY 8 BARRELS OF CRUDE OIL WERE RELEASED FROM THE HUDSON FEDERAL 4\" REPORTING-REGULATED-ONLY POLYETHYLENE PIPELINE. THE CAUSE OF THE INCIDENT IS UNDER INVESTIGATION AND A SUPPLEMENTAL REPORT WILL BE SUBMITTED ONCE THE INVESTIGATION HAS BEEN COMPLETED. SUPPLEMENTAL NARRATIVE: THE CAUSE OF THE INCIDENT WAS DETERMINED TO BE A MATERIAL FAILURE OF THE WELD DURING ORIGINAL CONSTRUCTION. TO PREVENT FUTURE RELEASES, PLAINS REPAIRED THE SECTION OF PIPING THAT FAILED."}
20210010Hazardous liquid (gravity / reporting-regulated)20212021-01-26 09:00:00BELLE FOURCHE PIPELINE CO1248WYCAMPBELLWESTON44.90565-105.523350018039.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/25/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210010", "SUPPLEMENTAL_NUMBER": "34915", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "1248", "NAME": "BELLE FOURCHE PIPELINE CO", "OPERATOR_STREET_ADDRESS": "455 N POPLAR ST.", "OPERATOR_CITY_NAME": "CASPER", "OPERATOR_STATE_ABBREVIATION": "WY", "OPERATOR_POSTAL_CODE": "82602", "LOCAL_DATETIME": "1/26/2021 9:00", "TIME_ZONE": "MOUNTAIN", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "44.90565", "LOCATION_LONGITUDE": "-105.52335", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "5", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "5", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "1/26/2021 9:00", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "YES", "PARTY_INITIATED_COMMUNICATION": "OPERATOR", "INITIAL_RESPONDER_COM_DATETIME": "1/26/2021 13:20", "ON_SITE_DATETIME": "1/26/2021 9:00", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "WY", "ONSHORE_CITY_NAME": "WESTON", "ONSHORE_COUNTY_NAME": "CAMPBELL", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "6", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "41", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "3000", "EST_COST_GAS_RELEASED": "260", "EST_COST_PROP_DAMAGE": "5376", "EST_COST_EMERGENCY": "9403", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "18039", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "INTERNAL CORROSION", "PREPARER_NAME": "DOUGLAS THACKER", "PREPARER_TITLE": "COMPLIANCE COORDINATOR", "PREPARER_EMAIL": "doug.thacker@truecos.com", "PREPARER_TELEPHONE": "3072660320", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON JANUARY 26, 2021, AN OPERATIONS EMPLOYEE WAS RECORDING LACT METER READINGS AT TWO LOCATIONS IN THE AREA. AT APPROXIMATELY 9:00 AM MST HE WAS COMING OUT OF THE LOCATIONS WHEN HE NOTICED CRUDE OIL ON THE RIGHT OF WAY. HE IMMEDIATELY NOTIFIED SUPERVISORS AND INFORMED THEM THAT OIL WAS LOCATED ON OUR RIGHT OF WAY AND THEN BEGAN TO SHUT IN FACILITIES IN THE AREA. A COMPANY ROUSTABOUT CREW WAS THEN CONTACTED AND RESPONDED TO THE RELEASE LOCATION AND CONTAINED IT. ONCE THE RELEASE WAS CONTAINED, THE ROUSTABOUT CREW EXPOSED THE PIPELINE TO DETERMINE THE LOCATION OF THE LEAK AND SUBSEQUENTLY REPLACED A SECTION OF PIPE APPROXIMATELY 73 FT. IN LENGTH. THE LINE WAS THEN PLACED BACK INTO SERVICE. INITIAL FIELD EXAMINATION OF THE REMOVED PIPE INDICATED THE RELEASE WAS DUE TO INTERNAL CORROSION. THE REMOVED SECTION OF PIPE WILL NOT BE SUBMITTED FOR METALLURGICAL ANALYSIS; HOWEVER, INTERNAL INSPECTION OF THE PIPELINE WITH AN ILI TOOL IS PLANNED. ALTHOUGH THE RELEASE WAS NOT REQUIRED TO BE REPORTED TO THE NRC OR THE STATE OF WYOMING, A COURTESY TELEPHONIC NOTIFICATION WAS MADE TO THE WYOMING DEQ SPILL COORDINATOR ADVISING THEM OF THE RELEASE. THE RELEASE DID NOT IMPACT SURFACE WATER, GROUND WATER OR WILDLIFE; HOWEVER AN APPROXIMATE 120 FT. BY 30 FT. AREA OF SOILS WERE CONTAMINATED TO ABOUT 1 INCH IN DEPTH. THE CONTAMINATED SOILS WERE EXCAVATED AND REPLACED WITH CLEAN FILL DIRT. THE CONTAMINATED SOILS WILL BE DISPOSED OF IN ACCORDANCE WITH WYOMING DEQ REQUIREMENTS."}
20210011Hazardous liquid (gravity / reporting-regulated)20212021-01-25 13:00:00HOLLY ENERGY PARTNERS - OPERATING, L.P.32011NMLEANOT WITHIN A MUNICIPALITY32.4925-103.25640093375.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "2/26/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210011", "SUPPLEMENTAL_NUMBER": "35011", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "32011", "NAME": "HOLLY ENERGY PARTNERS - OPERATING, L.P.", "OPERATOR_STREET_ADDRESS": "2323 VICTORY AVE. SUITE 1400", "OPERATOR_CITY_NAME": "DALLAS", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "75219", "LOCAL_DATETIME": "1/25/2021 13:00", "TIME_ZONE": "MOUNTAIN", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.4925", "LOCATION_LONGITUDE": "-103.2564", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "821", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "548.16", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "1/26/2021 10:55", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "1/26/2021 10:55", "NRC_RPT_DATETIME": "1/26/2021 11:50", "NRC_RPT_NUM": "1296745", "ADDITIONAL_NRC_REPORT_NUMBERS": "1296838", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "NM", "ONSHORE_CITY_NAME": "NOT WITHIN A MUNICIPALITY", "ONSHORE_COUNTY_NAME": "LEA", "FEDERAL": "NO", "LOCATION_TYPE": "ORIGINATED ON OPERATOR-CONTROLLED PROPERTY, BUT THEN FLOWED OR MIGRATED OFF THE PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "6.625", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "14", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "YES", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "22675", "EST_COST_PROP_DAMAGE": "4200", "EST_COST_EMERGENCY": "40000", "EST_COST_ENVIRONMENTAL": "26500", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "93375", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "EXTERNAL CORROSION", "PREPARER_NAME": "BRIDGETTE TAYLOR", "PREPARER_TITLE": "PIPELINE REGULATORY MANAGER", "PREPARER_EMAIL": "bridgette.taylor@hollyenergy.com", "PREPARER_TELEPHONE": "214-954-6652", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "BRIDGETTE TAYLOR", "LOCAL_CONTACT_EMAIL": "bridgette.taylor@hollyenergy.com", "LOCAL_CONTACT_TELEPHONE": "214-954-6652", "NARRATIVE": "ON JANUARY 26, 2021, A FIELD TECHNICIAN WAS PERFORMING DAILY GAUGING ALONG THE 6\" EMSC TO MONUMENT LINE AND, UPON COMPLETING THEIR REPORT, IDENTIFIED AN IMBALANCE IN THEIR FINAL NUMBERS (BEING SHORT 821 BBLS). THE TECHNICIAN IMMEDIATELY BEGAN DRIVING THE LINE WHEN THEY CAME ACROSS THE POINT OF RELEASE. THE TECHNICIAN THEN CONTACTED BOTH THE CONTROL CENTER (IN ARTESIA, NM) AND THEIR IMMEDIATE SUPERVISOR AT APPX. 10:55 MST TO CONFIRM A PRODUCT RELEASE OF SOUR CRUDE. THE TECHNICIAN THEN BEGAN SHUTTING DOWN MOVS ALONG THE IMPACTED AREAS OF THE LINE; ALL OF WHICH WAS COMPLETED BY APPX. 11:52 MST. SHORTLY THEREAFTER, VAC TRUCKS BEGAN TO ARRIVE ONSITE TO START REMOVAL OF FREE LIQUIDS. TO NOTE, WHILE THIS IS A NON-REGULATED ASSET, DUE TO INITIAL INTERPRETATION OF NEW LANGUAGE WITHIN 49 CFR 195.15 THAT TOOK EFFECT ON JANUARY 1, 2021; THIS INCIDENT WAS REPORTED TO THE NRC AT APPX. 11:50 MST. SUBSEQUENTLY, IT WAS CLARIFIED (BY DOT/PHMSA) THAT IMMEDIATE NOTIFICATION WAS NOT REQUIRED AND ONLY A 30-DAY WRITTEN REPORT WOULD NEED TO BE SUBMITTED. ADDITIONALLY, AT APPX. 12:36 MST, TELEPHONIC NOTIFICATION WAS ALSO MADE TO THE NEW MEXICO OIL CONVERSATION DISTRICT (NMOCD). ROOT CAUSE IS DETERMINED TO BE AS A RESULT OF EXTERNAL CORROSION."}
20210012Hazardous liquid (gravity / reporting-regulated)20212021-02-02 14:15:00BRIDGER PIPELINE LLC31878NDDUNN COUNTYKILLDEER47.51705-102.854770046200.0INCORRECT OPERATIONCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/2/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210012", "SUPPLEMENTAL_NUMBER": "35478", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "31878", "NAME": "BRIDGER PIPELINE LLC", "OPERATOR_STREET_ADDRESS": "455 N. POPLAR ST.", "OPERATOR_CITY_NAME": "CASPER", "OPERATOR_STATE_ABBREVIATION": "WY", "OPERATOR_POSTAL_CODE": "82602", "LOCAL_DATETIME": "2/2/2021 14:15", "TIME_ZONE": "MOUNTAIN", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "47.51705", "LOCATION_LONGITUDE": "-102.85477", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "260", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "260", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/2/2021 14:15", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "YES", "PARTY_INITIATED_COMMUNICATION": "OPERATOR", "INITIAL_RESPONDER_COM_DATETIME": "2/3/2021 8:24", "ON_SITE_DATETIME": "2/2/2021 14:15", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "ND", "ONSHORE_CITY_NAME": "KILLDEER", "ONSHORE_COUNTY_NAME": "DUNN COUNTY", "FEDERAL": "NO", "LOCATION_TYPE": "ORIGINATED ON OPERATOR-CONTROLLED PROPERTY, BUT THEN FLOWED OR MIGRATED OFF THE PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "6.625", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "9.25", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "2000", "EST_COST_GAS_RELEASED": "600", "EST_COST_PROP_DAMAGE": "500", "EST_COST_EMERGENCY": "43100", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "46200", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "INCORRECT OPERATION", "CAUSE_DETAILS": "PIPELINE OR EQUIPMENT OVERPRESSURED", "PREPARER_NAME": "KEVIN PENA", "PREPARER_TITLE": "PIPELINE COMPLIANCE COORDINATOR", "PREPARER_EMAIL": "kevin.pena@truecos.com", "PREPARER_TELEPHONE": "4066873304", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON FEBRUARY 2, 2021, AT 2:15 PM, OPERATOR PERSONNEL WERE TRAVELING NEAR THE BRANDVICK STATION LOCATION WHEN THEY NOTICED CRUDE OIL ON THE RIGHT OF WAY. SUPERVISORS WERE IMMEDIATELY NOTIFIED AND ACTIONS WERE TAKEN TO SHUT IN THE FACILITIES ON SITE. THE LEAK WAS ISOLATED AT APPROXIMATELY 2:21 PM, AND RESOURCES WERE BROUGHT TO THE SITE TO COMPLETE REMEDIATION. A SECTION OF 6\" ABOVE GROUND PIPING WAS FOUND TO BE THE SOURCE OF THE SPILL, AND A TOTAL OF 11' OF PIPE WAS REMOVED. TWO 6\" - 600# BLIND FLANGES WERE INSTALLED, AND ARE CURRENTLY STILL IN PLACE. THE DAMAGED PIPE WAS TRANSPORTED TO COMPANY HEADQUARTERS AND WILL BE SUBJECT TO ADDITIONAL ANALYSIS TO IDENTIFY THE ROOT CAUSE OF THE FAILURE. NOTE: FURTHER ANALYSIS CONFIRMED THAT THE SECTION OF ISOLATED ABOVE GROUND PIPING FAILED FROM OVERPRESSURIZATION. THE RELEASE DID NOT IMPACT SURFACE WATER, GROUND WATER, OR WILDLIFE. CONTAMINATED SOILS WERE EXCAVATED AND REPLACED WITH CLEAN FILL DIRT. THOSE SOILS WILL BE DISPOSED OF IN ACCORDANCE WITH NORTH DAKOTA DEQ REQUIREMENTS."}
20210013Hazardous liquid (gravity / reporting-regulated)20212021-02-11 17:30:00ENERGY TRANSFER COMPANY32099TXMIDLANDODESSA31.782061-102.122981002844.0EQUIPMENT FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/3/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210013", "SUPPLEMENTAL_NUMBER": "34945", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "32099", "NAME": "ENERGY TRANSFER COMPANY", "OPERATOR_STREET_ADDRESS": "1300 MAIN STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/11/2021 17:30", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "31.782061", "LOCATION_LONGITUDE": "-102.122981", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "2.4", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "2.4", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/11/2021 17:00", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/11/2021 17:00", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "ODESSA", "ONSHORE_COUNTY_NAME": "MIDLAND", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "THREADED FITTING", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "10", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "144", "EST_COST_PROP_DAMAGE": "1000", "EST_COST_EMERGENCY": "0", "EST_COST_ENVIRONMENTAL": "1700", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "2844", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "EQUIPMENT FAILURE", "CAUSE_DETAILS": "THREADED CONNECTION/COUPLING FAILURE", "PREPARER_NAME": "CHRISTOPHER PALAFOX", "PREPARER_TITLE": "SPECIALIST REGULATORY COMPLIANCE", "PREPARER_EMAIL": "christopher.palafox@energytransfer.com", "PREPARER_TELEPHONE": "713-989-4464", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON FEBRUARY 11, 2021 AT APPROXIMATELY 17:00 A COMPANY EMPLOYEE DISCOVERED A CRUDE OIL SPILL DURING COLD WEATHER PREPARATION AT THE CONCHO WAMPA PUMP SITE. AT 17:30 THE EMPLOYEE CONFIRMED THAT THE SPILL CAME FROM AN 8-INCH PIPE ON THE SUCTION SIDE OF AN INJECTION PUMP ON THE CT203 COG WAMPA 6 INCH NON-REGULATED GATHERING PIPELINE. THE PUMP WAS STOPPED AND THE SPILLED WAS SECURED. IT WAS ALSO CONFIRMED THAT THE THREADED FITTING FAILED ON THE SUCTION PIPING. A THIRD-PARTY COMPANY WAS CALLED TO CLEAN UP ALL FREE PRODUCT AND REMEDIATE THE SOIL. A NEW FITTING WAS INSTALLED AND AT APPROXIMATELY 18:30 THE INJECTION PUMP WAS BACK IN SERVICE. THE CAUSE OF THE THREADED FITTING FAILURE WAS DUE TO POSSIBLE THREAD DEFECTS. TO PREVENT FUTURE SPILLS, EMPLOYEES WILL PERFORM ROUTINE VISUAL INSPECTIONS ON THE INJECTION PUMP SUCTION PIPE TREADED FITTINGS."}
20210014Hazardous liquid (gravity / reporting-regulated)20212021-02-08 08:50:00HILAND CRUDE, LLC32619NDMCKENZIEWATFORD CITY48.02507-103.29848007500.0MATERIAL FAILURE OF PIPE OR WELDCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/5/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210014", "SUPPLEMENTAL_NUMBER": "34955", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "32619", "NAME": "HILAND CRUDE, LLC", "OPERATOR_STREET_ADDRESS": "1001 LOUISIANA ST SUITE 1000", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/8/2021 8:50", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "48.02507", "LOCATION_LONGITUDE": "-103.29848", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "4.8", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "4.8", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/8/2021 8:50", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/8/2021 8:50", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "ND", "ONSHORE_CITY_NAME": "WATFORD CITY", "ONSHORE_COUNTY_NAME": "MCKENZIE", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "JOINT, INCLUDING HEAT-AFFECTED ZONE", "PIPE_TYPE": "", "JOINT_SUBTYPE": "PIPE GIRTH JOINT", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "4.5", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "21.7", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "NO", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "0", "EST_COST_PROP_DAMAGE": "7500", "EST_COST_EMERGENCY": "0", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "7500", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "MATERIAL FAILURE OF PIPE OR WELD", "CAUSE_DETAILS": "DESIGN-, CONSTRUCTION-, INSTALLATION-, OR FABRICATION-RELATED", "PREPARER_NAME": "CLAYTON THEDINGER", "PREPARER_TITLE": "ENGINEER-PIPELINE", "PREPARER_EMAIL": "clayton_thedinger@kindermorgan.com", "PREPARER_TELEPHONE": "713-420-5629", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "MIKE OKONEK", "LOCAL_CONTACT_EMAIL": "mike_okonek@kindermorgan.com", "LOCAL_CONTACT_TELEPHONE": "701-713-0438", "NARRATIVE": "A HILAND CRUDE EMPLOYEE WAS ONSITE AT A WELL PAD THE MORNING OF 2/8/2021 PREPARING TO SHIP A TANK OF OIL WHEN HE DISCOVERED CRUDE OIL IN THE LINED CONTAINMENT COMING FROM THE DISCHARGE HEADER OF THE POLK 2 & 3 LINE AT 8:50 AM CST. THE HILAND CRUDE EMPLOYEE IMMEDIATELY ISOLATED THE HEADER TO STOP THE LEAK. THE CRUDE OIL SPILL WAS CLEANED UP USING A VAC TRUCK THE SAME DAY AND ALL THE CRUDE OIL WAS ABLE TO BE RECOVERED. THE TOTAL RELEASE AMOUNT WAS DETERMINED TO BE 4.8 BBLS. THIS RELEASE OCCURRED FROM A 4.5 INCH GATHERING LINE IN MCKENZIE COUNTY, ND. THEREFORE, THIS LINE FALLS UNDER THE REPORTING-REGULATED-ONLY GATHERING LINE CRITERIA. NO NRC NOTIFICATION WAS REQUIRED DUE TO THE EXCEPTION OUTLINED IN 49 CFR 195.15(C)(2); HOWEVER, A 30 DAY ACCIDENT REPORT IS REQUIRED PER 195.15. DURING THE INVESTIGATION, IT WAS DETERMINED THAT THE CRUDE OIL SPILL CAME FROM A PINHOLE LEAK AT THE WELD OF A 4 INCH X 2 INCH STANDARD WALL THICKNESS CONCENTRIC REDUCER ON THE DISCHARGE HEADER. THE PINHOLE LEAK FORMED ON THE 4 INCH SIDE OF THE REDUCER. THE CAUSE OF THE PINHOLE WAS A RESULT OF THE VIBRATIONS EXPERIENCED ON THE HEADER FROM THE PUMP. THE INVESTIGATION CONCLUDED WITH DECIDING TO REPLACE THE REDUCER WITH AN EXTRA HEAVY WALL THICKNESS ONE INSTEAD OF THE EXISTING STANDARD WALL FITTING TO HELP REDUCE THE VIBRATION IMPACT. THE REPAIRS WERE COMPLETED ON 2/11/2021 AND THE LINE WAS RETURNED TO SERVICE THAT SAME DAY."}
20210015Hazardous liquid (gravity / reporting-regulated)20212021-02-11 09:49:00ENERGY TRANSFER COMPANY32099TXLOVINGMENTONE31.68843-103.53522004760.0INCORRECT OPERATIONCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/9/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210015", "SUPPLEMENTAL_NUMBER": "34964", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "32099", "NAME": "ENERGY TRANSFER COMPANY", "OPERATOR_STREET_ADDRESS": "1300 MAIN STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/11/2021 9:49", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "31.68843", "LOCATION_LONGITUDE": "-103.53522", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "3.1", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "3.1", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/11/2021 9:49", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/11/2021 9:49", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "MENTONE", "ONSHORE_COUNTY_NAME": "LOVING", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "SAMPLE PORT VALVE ON LACT UNIT", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "0.08", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "185", "EST_COST_PROP_DAMAGE": "0", "EST_COST_EMERGENCY": "200", "EST_COST_ENVIRONMENTAL": "4375", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "4760", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "INCORRECT OPERATION", "CAUSE_DETAILS": "VALVE LEFT OR PLACED IN WRONG POSITION, BUT NOT RESULTING IN A TANK, VESSEL, OR SUMP/SEPARATOR OVERFLOW OR FACILITY OVERPRESSURE", "PREPARER_NAME": "CHRIS PALAFOX", "PREPARER_TITLE": "REGULATORY COMPLIANCE SPECIALIST", "PREPARER_EMAIL": "chris.palafox@energytransfer.com", "PREPARER_TELEPHONE": "713-989-4464", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "CHRIS PALAFOX", "LOCAL_CONTACT_EMAIL": "chris.palafox@energytransfer.com", "LOCAL_CONTACT_TELEPHONE": "713-989-4464", "NARRATIVE": "ON FEBRUARY 11, 2021 AT APPROXIMATELY 09:49 A COMPANY EMPLOYEE DISCOVERED A CRUDE OIL LEAK FROM A 1/4 INCH SAMPLE PORT VALVE HALF OPENED ON A LACT UNIT DURING HIS DAILY ROUNDS AT THE BUSH MASTER LACT STATION AND NOTIFIED OPERATIONS. THE EMPLOYEE CLOSED THE SAMPLE PORT VALVE, THUS STOPPING THE LEAK AND LOCKED IT CLOSED. THE VALVE WAS LEFT OPENED DURING MEASUREMENT MAINTENANCE ON THE LACT UNIT THE DAY BEFORE. A THIRD PARTY WAS CALLED TO CLEAN UP ALL THE FREE PRODUCT AND REMEDIATE THE SOIL. THE LACT UNIT IS ON THE BUSH MASTER 8 INCH NON REGULATED GATHERING LINE ON OUR VERMEJO GATHERING SYSTEM. THE LACT UNIT HAD 5 PSI ON IT WAS DOWN AND NOT RUNNING AT THE TIME THE LEAK WAS FOUND. TO PREVENT THIS FROM FUTURE SPILLS/LEAKS, ALL VALVES ON LACT UNITS ON THE VERMEJO GATHERING SYSTEM ARE BEING INSPECTED AND PLACING LOCKS ON THE VALVES TO PREVENT BEING BUMPED OPENED OR PHYSICALLY OPENED UNLESS THE LOCK IS REMOVED."}
20210016Hazardous liquid (gravity / reporting-regulated)20212021-02-17 17:00:00STATELINE CRUDE, LLC39589TXLOVINGORLA31.88132-103.8603001350.0NATURAL FORCE DAMAGECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/10/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210016", "SUPPLEMENTAL_NUMBER": "37164", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "39589", "NAME": "STATELINE CRUDE, LLC", "OPERATOR_STREET_ADDRESS": "16211 LA CANTERA PARKWAY SUITE 202", "OPERATOR_CITY_NAME": "SAN ANTONIO", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "78256", "LOCAL_DATETIME": "2/17/2021 17:00", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "31.88132", "LOCATION_LONGITUDE": "-103.8603", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "0.48", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "0.48", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "THE PRODUCER ONSITE NOTICED THE LEAK AND CALLED THE OPERATOR.", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "2/17/2021 16:00", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/17/2021 17:00", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "ORLA", "ONSHORE_COUNTY_NAME": "LOVING", "FEDERAL": "NO", "LOCATION_TYPE": "ORIGINATED ON OPERATOR-CONTROLLED PROPERTY, BUT THEN FLOWED OR MIGRATED OFF THE PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "VALVE", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "MATERIAL OTHER THAN CARBON STEEL", "MATERIAL_DETAILS": "TEFLON SEAL", "PERCENT_PIPE_SMYS": "", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "20", "EST_COST_PROP_DAMAGE": "300", "EST_COST_EMERGENCY": "500", "EST_COST_ENVIRONMENTAL": "530", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "1350", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "NATURAL FORCE DAMAGE", "CAUSE_DETAILS": "TEMPERATURE", "PREPARER_NAME": "JON HOFFMAN", "PREPARER_TITLE": "REGULATORY MANAGER", "PREPARER_EMAIL": "jhoffman@howardep.com", "PREPARER_TELEPHONE": "2102982229", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "GARY VAUGHN", "LOCAL_CONTACT_EMAIL": "gvaughn@howardep.com", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "FOLLOWING SNOW, ICE, AND FREEZING TEMPERATURES, AN 8\" BALL VALVE FROZE AND CAUSED THE TEFLON SEAL TO FAIL ON THE LATERAL N PIPELINE. THE PRODUCER ONSITE NOTICED THE LEAK AND CONTACTED THE OPERATOR. THE OPERATOR ARRIVED ONSITE, ISOLATED THE LEAKING VALVE, AND REPLACED THE VALVE WITH A BLIND FLANGE. THE REPAIR AND SOIL REMEDIATED WAS ALL DONE WITHIN THE SAME DAY AS THE LEAK (2/17/2021). THE PLAN TO PREVENT RECURRENCE INCLUDES PERFORMING PATROLS ON THE PIPELINE SYSTEM FOLLOWING EXTREME WEATHER OR NATURAL DISASTER EVENTS."}
20210017Hazardous liquid (gravity / reporting-regulated)20212021-02-16 12:00:00CAMINO REAL GATHERING CO LLC39229TXLASALLECOTULLA28.469656-99.39479900103225.0EQUIPMENT FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/12/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210017", "SUPPLEMENTAL_NUMBER": "35207", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "39229", "NAME": "CAMINO REAL GATHERING CO LLC", "OPERATOR_STREET_ADDRESS": "1001 LOUISIANA ST SUITE 1000", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/16/2021 12:00", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "28.469656", "LOCATION_LONGITUDE": "-99.394799", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "39", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "35", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "TELEPHONIC NOTIFICATION FROM FACILITY OWNER PERSONNEL.", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "2/16/2021 12:30", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "YES", "PARTY_INITIATED_COMMUNICATION": "OPERATOR", "INITIAL_RESPONDER_COM_DATETIME": "2/16/2021 16:15", "ON_SITE_DATETIME": "2/16/2021 12:30", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "YES", "OSRO_OPERATOR_NOTIFIED_DT": "2/16/2021 13:30", "OSRO_ARRIVED_ON_SITE_DT": "2/16/2021 17:15", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "COTULLA", "ONSHORE_COUNTY_NAME": "LASALLE", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "FLANGE CONNECTION BETWEEN PIPING & VALVE", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "MATERIAL OTHER THAN CARBON STEEL", "MATERIAL_DETAILS": "GARLOCK BLUE GUARD - ARAMID FIBERS", "PERCENT_PIPE_SMYS": "", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "YES", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "225", "EST_COST_PROP_DAMAGE": "3000", "EST_COST_EMERGENCY": "85000", "EST_COST_ENVIRONMENTAL": "15000", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "103225", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "EQUIPMENT FAILURE", "CAUSE_DETAILS": "OTHER EQUIPMENT FAILURE", "PREPARER_NAME": "JAMES PALACIOS", "PREPARER_TITLE": "SPECIALIST-TECHNICAL COMPLIANCE", "PREPARER_EMAIL": "james_palacios@kindermorgan.com", "PREPARER_TELEPHONE": "713-420-7004", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "ROCKY WILSON", "LOCAL_CONTACT_EMAIL": "rocky_wilson@kindermorgan.com", "LOCAL_CONTACT_TELEPHONE": "713-420-3222", "NARRATIVE": "2/16/21 AT APPROXIMATELY 12PM CST, TEXAS INTERNATIONAL OPERATIONS PERSONNEL NOTIFIED CAMINO REAL GATHERING OPERATIONS PERSONNEL THAT THERE WAS A RELEASE OF CRUDE OIL AT THE TEXAS INTERNATIONAL 4\" PRODUCTION FACILITY LOCATED IN COTULLA TX, LASALLE COUNTY . CAMINO REAL PERSONNEL WERE DISPATCHED TO THE SITE AND FOUND A FAILED GASKET TO BE THE SOURCE OF THE RELEASE. THE FACILITY WAS LOCKED OUT AND ISOLATED. BASED OF AN INITIAL ESTIMATE OF 39 BARRELS OF CRUDE OIL RELEASED, CAMINO REAL'S OIL SPILL RESPONSE PLAN WAS ACTIVATED, OSRO WAS CALLED, AND CLEANUP INITIATED. THE RAILROAD COMMISSION OF TEXAS OIL AND GAS DIVISION WAS ALSO NOTIFIED TELEPHONICALLY. TESTS ARE BEING PERFORMED TO DETERMINE IF A LONG TERM REMEDIATION WILL BE REQUIRED AND IF SO, THEY WILL BE NOTED ON THE SUPPLEMENTAL AND FINAL REPORT. : UPDATE 4/23/2021 - NO LONG TERM REMEDIATION NEEDED, SOIL REMOVAL AND REPLACEMENT HAS BEEN PERFORMED ON THE SITE. AN INTERNAL INVESTIGATION TO DETERMINE THE ROOT CAUSE AND PLAN TO PREVENT REOCCURRENCE ARE ALSO BEING PERFORMED AND RESULTS WILL BE SUBMITTED ON A FUTURE SUPPLEMENTAL AND FINAL REPORT. :UPDATE 4/23/2021 THE ROOT CAUSE OF THE EQUIPMENT FAILURE WAS \"TEMPERATURE EXTREMES\", ON THE DATE OF THE RELEASE TEXAS WAS EXPERIENCING WINTER STORM URI AND ASSOCIATED FREEZING TEMPERATURES. THE FAILED COMPONENT WAS A GARLOCK FIBER GASKET LOCATED IMMEDIATELY UPSTREAM OF A ISOLATION VALVE THAT CLOSES WHEN PNEUMATIC SUPPLY GAS PRESSURE DROPS BELOW 80PSI. THE EFFECTS OF PROLONGED, UNUSUALLY COLD TEMPERATURES ON THE SUPPLY GAS LINE TO THE ISOLATION VALVE CAUSED THE ISOLATION VALVE TO CLOSE UNEXPECTEDLY, WHILE THE SYSTEMS POSITIVE DISPLACEMENT PUMP CONTINUED TO OPERATE LEADING TO EVENTUAL GASKET FAILURE. TO PREVENT REOCCURRENCE CAMINO REAL HAS ADDED PROGRAMMING LANGUAGE FOR PUMP SHUTDOWN WHEN THE ISOLATION VALVE GOES CLOSED, REPLACED THE FIBER GASKET WITH A FLEXITALLIC / SPIRAL WOUND GASKET, AND EVALUATED OTHER CAMINO REAL GATHERING SITES FOR SIMILAR POTENTIAL EXPOSURE AND CORRECTED IF NEEDED."}
20210018Hazardous liquid (gravity / reporting-regulated)20212021-02-14 03:02:00BRIDGER PIPELINE LLC31878MTFALLONBAKER46.389071-104.448203005500.0EQUIPMENT FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/15/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210018", "SUPPLEMENTAL_NUMBER": "35002", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "31878", "NAME": "BRIDGER PIPELINE LLC", "OPERATOR_STREET_ADDRESS": "455 N. POPLAR ST.", "OPERATOR_CITY_NAME": "CASPER", "OPERATOR_STATE_ABBREVIATION": "WY", "OPERATOR_POSTAL_CODE": "82602", "LOCAL_DATETIME": "2/14/2021 3:02", "TIME_ZONE": "MOUNTAIN", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "46.389071", "LOCATION_LONGITUDE": "-104.448203", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "5", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "5", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "SCADA-BASED INFORMATION (SUCH AS ALARM(S), ALERT(S), EVENT(S), AND/OR VOLUME OR PACK CALCULATIONS)", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "2/14/2021 3:02", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/14/2021 5:20", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "YES", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "MT", "ONSHORE_CITY_NAME": "BAKER", "ONSHORE_COUNTY_NAME": "FALLON", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "THREADED PIPE FITTING", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "0.01", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "200", "EST_COST_PROP_DAMAGE": "300", "EST_COST_EMERGENCY": "5000", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "5500", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "EQUIPMENT FAILURE", "CAUSE_DETAILS": "THREADED CONNECTION/COUPLING FAILURE", "PREPARER_NAME": "KEVIN PENA", "PREPARER_TITLE": "PIPELINE COMPLIANCE COORDINATOR", "PREPARER_EMAIL": "kevin.pena@truecos.com", "PREPARER_TELEPHONE": "4066873304", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "", "LOCAL_CONTACT_EMAIL": "", "LOCAL_CONTACT_TELEPHONE": "", "NARRATIVE": "ON FEBRUARY 14, 2021 AT APPROXIMATELY 3:02 AM, THE CASPER CONTROL CENTER IDENTIFIED A LACK OF FLOW SHOWN BY THE INCOMING METER AT THE BAKER/BOWMAN STATION FACILITY. FIELD PERSONNEL WERE NOTIFIED AND THE LINE WAS SHUT DOWN. WHEN PERSONNEL ARRIVED ON SITE, THEY IDENTIFIED A CRACKED FITTING ON A PIECE OF THREADED PIPE. THE INITIAL FIELD INVESTIGATION FOUND THAT THERE WAS A HOSE CONNECTED TO A PRESSURE TRANSMITTER FROM A CONTROL VALVE WHICH HAD FROZEN IN THE EXTREME COLD. THIS FROZEN HOSE THEN CAUSED THE CONTROL VALVE TO CLOSE ERRONEOUSLY. THE CONTROL VALVE CLOSURE SUBSEQUENTLY CAUSED LINE PRESSURE TO RELIEVE TO THE RELIEF TANKS ON SITE. THE CHATTERING OF THE RELIEF VALVE IS BELIEVED TO HAVE CREATED EXCESSIVE VIBRATION, WHICH COMBINED WITH THE EXTREMELY COLD TEMPERATURES, LED TO THE FAILURE OF A THREADED PIPE NIPPLE. THE FAILURE OF THE THREADED FITTING RESULTED IN APPROXIMATELY 5 BARRELS OF CRUDE OIL BEING RELEASED INTO THE CONTAINMENT AREA SURROUNDING THE EQUIPMENT. THE SPILL WAS FULLY CONTAINED ON OPERATOR PROPERTY IN THE CONTAINMENT AREA, AND THE RELEASE DID NOT IMPACT SURFACE WATER, GROUND WATER, OR WILDLIFE. IMPACTED SOILS WERE EXCAVATED AND DISPOSED OF IN ACCORDANCE WITH MONTANA DEQ REGULATIONS."}
20210019Hazardous liquid (gravity / reporting-regulated)20212021-02-17 13:30:00EOG RESOURCES, INC4461TXLA SALLECOTULLA28.58528-98.8628900350000.0EQUIPMENT FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/16/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210019", "SUPPLEMENTAL_NUMBER": "35010", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "4461", "NAME": "EOG RESOURCES, INC", "OPERATOR_STREET_ADDRESS": "1111 BAGBY ST. SKY LOBBY 2", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/17/2021 13:30", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "28.58528", "LOCATION_LONGITUDE": "-98.86289", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "285", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "270", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/17/2021 13:30", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/17/2021 13:30", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "COTULLA", "ONSHORE_COUNTY_NAME": "LA SALLE", "FEDERAL": "NO", "LOCATION_TYPE": "ORIGINATED ON OPERATOR-CONTROLLED PROPERTY, BUT THEN FLOWED OR MIGRATED OFF THE PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "VALVE BODY", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "2.19", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "70000", "EST_COST_GAS_RELEASED": "1000", "EST_COST_PROP_DAMAGE": "3000", "EST_COST_EMERGENCY": "3000", "EST_COST_ENVIRONMENTAL": "273000", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "350000", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "EQUIPMENT FAILURE", "CAUSE_DETAILS": "FAILURE OF EQUIPMENT BODY (EXCEPT PUMP), TANK PLATE, OR OTHER MATERIAL", "PREPARER_NAME": "JARED LANE", "PREPARER_TITLE": "PIPELINE FOREMAN", "PREPARER_EMAIL": "jared_lane@eogresources.com", "PREPARER_TELEPHONE": "(210) 775-8986", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "JARED LANE", "LOCAL_CONTACT_EMAIL": "jared_lane@eogresources.com", "LOCAL_CONTACT_TELEPHONE": "(210) 775-8986", "NARRATIVE": "ON 2/17/2021, OPERATOR'S EMPLOYEE DISCOVERED RELEASE AT 1:30 PM FROM VALVE SITE AND INITIATED SHUT DOWN PROCEDURES IMMEDIATELY. CRUDE OIL WAS DISCHARGING FROM 3\" BALL VALVE THAT WAS INTENDED FOR A BLOWDOWN VALVE. RELEASE CAME FROM BODY SEAM OF VALVE WHICH WAS NOT ALTERED BY OPERATOR. ADVERSE WEATHER CONDITIONS (BELOW FREEZING TEMPERATURES) MAY HAVE CONTRIBUTED TO FAILURE. OPERATOR THEN BEGAN REMEDIATION ACTIVITIES WHICH INCLUDED OIL RECOVERY FROM OPERATOR'S PAD SITE. AFTER 270 BBLS WERE RECOVERED BY VACUUM TRUCKS, EXCAVATION REMEDIATION BEGAN. DURING EXCAVATION REMEDIATION, OPERATOR NOTICED OIL HAD SLIGHTLY MIGRATED UNDERGROUND TO A 3RD PARTY OPERATOR'S PAD SITE AND ADJACENT LANDOWNER'S PROPERTY. OPERATOR ESTIMATES 15 BBLS OF PRODUCT HAD BEEN ABSORBED INTO THE SOIL. ALL CONTAMINATED SOIL WILL BE FULLY REMOVED AND ALL REQUIREMENTS BY TEXAS RAILROAD COMMISSION ARE BEING COMPLIED WITH TO THE FULLEST EXTENT. THE VALVE THAT FAILED WAS SENT TO MANUFACTURER TO INVESTIGATE. RESULTS ARE STILL PENDING."}
20210020Hazardous liquid (gravity / reporting-regulated)20212021-02-20 16:55:00HILAND CRUDE, LLC32619NDMOUNTRAILNEW TOWN48.077459-102.6136390020590.0EQUIPMENT FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/17/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210020", "SUPPLEMENTAL_NUMBER": "35016", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "32619", "NAME": "HILAND CRUDE, LLC", "OPERATOR_STREET_ADDRESS": "1001 LOUISIANA ST SUITE 1000", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/20/2021 16:55", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "48.077459", "LOCATION_LONGITUDE": "-102.613639", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "32.9", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "32.9", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "PRODUCER ALARM THAT OUR FACILITIES WERE UNAVAILABLE FOR DELIVERY.", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "2/20/2021 17:13", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/20/2021 17:13", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "ND", "ONSHORE_CITY_NAME": "NEW TOWN", "ONSHORE_COUNTY_NAME": "MOUNTRAIL", "FEDERAL": "YES", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "ANSI #150 FLANGE BOLTS/SUCTION DAMPENER.", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "30", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "NO", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "0", "EST_COST_PROP_DAMAGE": "1000", "EST_COST_EMERGENCY": "12990", "EST_COST_ENVIRONMENTAL": "6600", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "20590", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "EQUIPMENT FAILURE", "CAUSE_DETAILS": "NON-THREADED CONNECTION FAILURE", "PREPARER_NAME": "STEPHEN R. DINES", "PREPARER_TITLE": "ENGINEER", "PREPARER_EMAIL": "stephen_dines@kindermorgan.com", "PREPARER_TELEPHONE": "(719) 351-4199", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "TYLER HENGEL", "LOCAL_CONTACT_EMAIL": "tyler_hengel@kindermorgan.com", "LOCAL_CONTACT_TELEPHONE": "(701) 269-4745", "NARRATIVE": "ON FEBRUARY 20, AT 16:55 LOCAL TIME, HILAND CRUDE, LLC RECEIVED NOTICE OF A 32.9 BBL CRUDE OIL SPILL AT THE CORSICAN CENTRAL TANK BATTERY, OPERATED BY CONTINENTAL RESOURCES IN MOUNTRAIL COUNTY, NORTH DAKOTA. THE RELEASE WAS ENTIRELY CONTAINED IN THE PRODUCER'S LINED CONTAINMENT. THE SPILL RESULTED FROM A FAILURE OF TWO ANSI 150 FLANGE BOLTS ON THE HILAND CRUDE, LLC SUCTION DAMPENER DOWNSTREAM OF THE LEASE AUTOMATIC CUSTODY TRANSFER (LACT). THE SUCTION PRESSURE AT THE TIME OF THE RELEASE WAS ESTIMATED TO BE 60-65 PSIG. THE ANSI 150 PIPING HAD ADEQUATE THERMAL RELIEF AND WAS OPERATING NORMALLY PRIOR TO THE RELEASE. NO INJURIES REPORTED AND HILAND CRUDE, LLC RECOVERED ALL RELEASED PRODUCT. INVESTIGATION OF THE CAUSE OF THE EVENT DETERMINED THAT VIBRATION FROM THE SUCTION DAMPENER BROKE TWO MOUNTING BOLTS ON THE UNIT CAUSING A LEAK OF CRUDE OIL. THE APPARENT CAUSE OF THE VIBRATION WAS THE INADEQUATE INSPECTION OF INTERNAL SOFT GOODS (I.E., BLADDER/SEALS) WITHIN THE SUCTION DAMPENER. WHEN THE SOFT GOODS FAILED, THIS CAUSED THE UNIT TO BEGIN VIBRATING BREAKING TWO OF THE FOUR MOUNTING BOLTS. THE SUCTION DAMPENER WAS REPAIRED AND RETURNED TO SERVICE. HILAND CRUDE, LLC HAS INITIATED A REVIEW OF SIMILAR DEVICES AT OTHER LOCATIONS TO IDENTIFY AND CORRECT ANY VIBRATION ISSUES."}
20210021Hazardous liquid (gravity / reporting-regulated)20212021-02-20 13:05:00HILAND CRUDE, LLC32619NDWILLIAMSWILLISTON48.45473-103.29960020329.0INCORRECT OPERATIONCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/18/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210021", "SUPPLEMENTAL_NUMBER": "35024", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "32619", "NAME": "HILAND CRUDE, LLC", "OPERATOR_STREET_ADDRESS": "1001 LOUISIANA ST SUITE 1000", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/20/2021 13:05", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "48.45473", "LOCATION_LONGITUDE": "-103.2996", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "3.2", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "3.2", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "3RD PARTY OPERATOR ON THEIR PROPERTY NOTIFIED HILAND CRUDE, LLC", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "2/20/2021 13:07", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/20/2021 13:07", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "ND", "ONSHORE_CITY_NAME": "WILLISTON", "ONSHORE_COUNTY_NAME": "WILLIAMS", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "20 HORSEPOWER TRI-PLEX PUMP", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "72", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "180", "EST_COST_PROP_DAMAGE": "150", "EST_COST_EMERGENCY": "0", "EST_COST_ENVIRONMENTAL": "19999", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "20329", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "INCORRECT OPERATION", "CAUSE_DETAILS": "VALVE LEFT OR PLACED IN WRONG POSITION, BUT NOT RESULTING IN A TANK, VESSEL, OR SUMP/SEPARATOR OVERFLOW OR FACILITY OVERPRESSURE", "PREPARER_NAME": "STEPHEN R. DINES", "PREPARER_TITLE": "ENGINEER", "PREPARER_EMAIL": "stephen_dines@kindermorgan.com", "PREPARER_TELEPHONE": "719 351-4199", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "MATT DIEPENHORST", "LOCAL_CONTACT_EMAIL": "matthew_diepenhorst@kindermorgan.com", "LOCAL_CONTACT_TELEPHONE": "701-713-0786", "NARRATIVE": "ON FEBRUARY 20, 2021, HILAND CRUDE, LLC CONFIRMED DISCOVERY OF A 3.2 BARRELS CRUDE OIL SPILL IN WILLIAMS COUNTY, ND AT A WELL PAD SITE OWNED AND OPERATED BY A LOCAL PRODUCER. ALL PRODUCT WAS CONTAINED WITHIN SECONDARY CONTAINMENT AND RECOVERED. NO INJURIES REPORTED. UPON INVESTIGATION, IT WAS DETERMINED THAT THE PUMP-CUP BLEED-VENT, ISOLATION VALVE WAS INADVERTENTLY LEFT OPEN AFTER PERFORMING MAINTENANCE ON THE VALVE, APPROXIMATELY TWO DAYS PRIOR TO THE EVENT, RESULTING IN THE 3.2 BBL SPILL. THE IMMEDIATE CAUSE OF THE RELEASE WAS FAILURE TO CLOSE THE PUMP-CUP BLEED-VENT VALVE ONCE MAINTENANCE WAS COMPLETE. THE ROOT CAUSE OF THE EVENT WAS THE OPERATOR'S LACK OF SITUATIONAL AWARENESS. HILAND CRUDE, LLC HAS INITIATED CORRECTIVE ACTION TO MARK OR TAG THE CORRECT POSITION OF ALL PUMP-CUP BLEED-VENT LINE VALVES AND SHARING THE LESSONS-LEARNED WITH ALL PERSONNEL WORKING AT THE WELL-PAD LOCATIONS TO PREVENT A REOCCURRENCE OF THIS TYPE OF EVENT."}
20210022Hazardous liquid (gravity / reporting-regulated)20212021-02-20 09:10:00ENTERPRISE CRUDE PIPELINE LLC30829TXMIDLANDMIDLAND31.8924-102.0728005042.0EQUIPMENT FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/19/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210022", "SUPPLEMENTAL_NUMBER": "35034", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "30829", "NAME": "ENTERPRISE CRUDE PIPELINE LLC", "OPERATOR_STREET_ADDRESS": "1100 LOUISIANA STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/20/2021 9:10", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "31.8924", "LOCATION_LONGITUDE": "-102.0728", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "0.71", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "0.71", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "THIRD PARTY, PRODUCER, NOTIFIED OPERATOR", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "2/20/2021 9:10", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/20/2021 11:15", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "MIDLAND", "ONSHORE_COUNTY_NAME": "MIDLAND", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "PUMP SEAL", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "0.01", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "42", "EST_COST_PROP_DAMAGE": "2200", "EST_COST_EMERGENCY": "2800", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "5042", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "EQUIPMENT FAILURE", "CAUSE_DETAILS": "PUMP OR PUMP-RELATED EQUIPMENT", "PREPARER_NAME": "YAROSLAV BIL", "PREPARER_TITLE": "PIPELINE COMPLIANCE ENGINEER", "PREPARER_EMAIL": "ybil@eprod.com", "PREPARER_TELEPHONE": "713-381-5650", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "YAROSLAV BIL", "LOCAL_CONTACT_EMAIL": "ybil@eprod.com", "LOCAL_CONTACT_TELEPHONE": "713-381-5650", "NARRATIVE": "ON 02/20/2021 AT 9:10 AM, AN ENTERPRISE TECHNICIAN WAS NOTIFIED BY A THIRD PARTY PRODUCER THAT THE SEAL ON PU-1000 AT PIONEER TEXAS TEN ZZ WAS ACTIVELY LEAKING. THE PUMP WAS ISOLATED AND THE LEAK WAS STOPPED. THE CAUSE OF THE LEAK WAS ATTRIBUTED TO LOW AMBIENT TEMPERATURE THAT CAUSED WATER WITHIN CRUDE IN THE PUMP SEAL TO FREEZE AND EXPAND RESULTING IN THE SEAL FAILURE. THE DAMAGED SEAL WAS REPLACED AND THE UNIT WAS MONITORED DURING RESTART. ALL SOIL WAS REMEDIATED."}
20210023Hazardous liquid (gravity / reporting-regulated)20212021-02-22 12:30:00ENTERPRISE CRUDE PIPELINE LLC30829TXMARTINN/A32.1623-102.150700252165.0MATERIAL FAILURE OF PIPE OR WELDCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/19/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210023", "SUPPLEMENTAL_NUMBER": "35289", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "30829", "NAME": "ENTERPRISE CRUDE PIPELINE LLC", "OPERATOR_STREET_ADDRESS": "1100 LOUISIANA STREET", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/22/2021 12:30", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.1623", "LOCATION_LONGITUDE": "-102.1507", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "80", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "80", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "OTHER", "ACCIDENT_DETAILS": "THE PRODUCER PERSONNEL NOTIFIED OPERATOR", "OPERATOR_TYPE": "", "INCIDENT_IDENTIFIED_DATETIME": "2/22/2021 13:00", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/22/2021 13:00", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "N/A", "ONSHORE_COUNTY_NAME": "MARTIN", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "4", "MATERIAL_INVOLVED": "MATERIAL OTHER THAN CARBON STEEL", "MATERIAL_DETAILS": "HIGH DENSITY POLYETHYLENE", "PERCENT_PIPE_SMYS": "", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "5000", "EST_COST_GAS_RELEASED": "5165", "EST_COST_PROP_DAMAGE": "200000", "EST_COST_EMERGENCY": "42000", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "252165", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "MATERIAL FAILURE OF PIPE OR WELD", "CAUSE_DETAILS": "DESIGN-, CONSTRUCTION-, INSTALLATION-, OR FABRICATION-RELATED", "PREPARER_NAME": "YAROSLAV BIL", "PREPARER_TITLE": "PIPELINE COMPLIANCE ENGINEER", "PREPARER_EMAIL": "ybil@eprod.com", "PREPARER_TELEPHONE": "713-381-5650", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "YAROSLAV BIL", "LOCAL_CONTACT_EMAIL": "ybil@eprod.com", "LOCAL_CONTACT_TELEPHONE": "713-381-5650", "NARRATIVE": "ON 2/22/2021 AT 12:30 PM, A THIRD PARTY PRODUCER NOTIFIED AN ENTERPRISE TECHNICIAN OF THE CRUDE OIL SPOT ON LID C95A RIGHT OF WAY. UPON ARRIVAL, THE TECHNICIAN SHUT DOWN AND ISOLATED THE PIPELINE. ALL SOIL WAS REMEDIATED, AND THE FAILED SEGMENT WAS CUT OUT AND REPLACED. THE FAILURE WAS DUE TO DAMAGE SUSTAINED ON THE PIPE WHEN BACKFILLING DURING CONSTRUCTION."}
20210024Hazardous liquid (gravity / reporting-regulated)20212021-02-19 13:30:00NUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC39348TXGLASSCOCKGARDEN CITY31.98103-101.72238001308.0NATURAL FORCE DAMAGECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/20/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210024", "SUPPLEMENTAL_NUMBER": "35064", "REPORT_TYPE": "SUPPLEMENTAL FINAL", "OPERATOR_ID": "39348", "NAME": "NUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC", "OPERATOR_STREET_ADDRESS": "8111 WESTCHESTER DRIVE", "OPERATOR_CITY_NAME": "DALLAS", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "75225", "LOCAL_DATETIME": "2/19/2021 13:30", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "31.98103", "LOCATION_LONGITUDE": "-101.72238", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "0.27", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "0.27", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/19/2021 13:30", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/19/2021 13:30", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "GARDEN CITY", "ONSHORE_COUNTY_NAME": "GLASSCOCK", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "VALVE", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "0.01", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "16", "EST_COST_PROP_DAMAGE": "820", "EST_COST_EMERGENCY": "0", "EST_COST_ENVIRONMENTAL": "472", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "1308", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "NATURAL FORCE DAMAGE", "CAUSE_DETAILS": "TEMPERATURE", "PREPARER_NAME": "ALONSO RODRIGUEZ", "PREPARER_TITLE": "MANAGER PIPELINE SAFETY", "PREPARER_EMAIL": "alonso.rodriguez@nustarenergy.com", "PREPARER_TELEPHONE": "8063360712", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "JAMES ROBERTSON", "LOCAL_CONTACT_EMAIL": "james.robertson@nustarenergy.com", "LOCAL_CONTACT_TELEPHONE": "18063711304", "NARRATIVE": "A NUSTAR OPERATOR DISCOVERED A LEAK AT THE XTO BERRY SITE. THE LEAK WAS ON A 2 INCH BALL VALVE LOCATED ON THE PIG TRAP. THE VALVE DEVELOPED A CRACK DUE TO FREEZING WATER TRAPPED IN THE VALVE. THE REGION HAD EXPERIENCED BELOW FREEZING WEATHER CONDITIONS OVER SEVERAL DAYS. THE VALVE WAS REPLACED AND CLEANED UP IMMEDIATELY."}
20210025Hazardous liquid (gravity / reporting-regulated)20212021-02-21 10:10:00NUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC39348TXMIDLANDMIDLAND31.71014-102.12163006111.0CORROSION FAILURECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/23/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210025", "SUPPLEMENTAL_NUMBER": "35065", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "39348", "NAME": "NUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC", "OPERATOR_STREET_ADDRESS": "8111 WESTCHESTER DRIVE", "OPERATOR_CITY_NAME": "DALLAS", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "75225", "LOCAL_DATETIME": "2/21/2021 10:10", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "31.71014", "LOCATION_LONGITUDE": "-102.12163", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "0.34", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "0.34", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/21/2021 10:10", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/21/2021 10:10", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "MIDLAND", "ONSHORE_COUNTY_NAME": "MIDLAND", "FEDERAL": "NO", "LOCATION_TYPE": "TOTALLY CONTAINED ON OPERATOR-CONTROLLED PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "PIPE", "PIPE_TYPE": "PIPE BODY", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "8.625", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "1.91", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "19", "EST_COST_PROP_DAMAGE": "5620", "EST_COST_EMERGENCY": "0", "EST_COST_ENVIRONMENTAL": "472", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "6111", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "CORROSION FAILURE", "CAUSE_DETAILS": "INTERNAL CORROSION", "PREPARER_NAME": "ALONSO RODRIGUEZ", "PREPARER_TITLE": "MANAGER PIPELINE SAFETY", "PREPARER_EMAIL": "alonso.rodriguez@nustarenergy.com", "PREPARER_TELEPHONE": "8063360712", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "JAMES ROBERTSON", "LOCAL_CONTACT_EMAIL": "james.robertson@nustarenergy.com", "LOCAL_CONTACT_TELEPHONE": "18063711304", "NARRATIVE": "A NUSTAR EMPLOYEE DISCOVERED A LEAK AT THE CONCHO WINDHAM TXL SITE. A PINHOLE WAS DISCOVERED ON THE 6 O'CLOCK POSITION OF THE PIG LAUNCHER. THE LAUNCHER WAS ISOLATED, DRAINED DOWN, AND REMOVED FOR REPAIR. THE CONTAMINATED SOIL WAS PLACED INTO A DRUM."}
20210026Hazardous liquid (gravity / reporting-regulated)20212021-02-23 10:55:00NUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC39348TXMARTINLENORAH32.27968-101.886820018588.0INCORRECT OPERATIONCRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/25/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210026", "SUPPLEMENTAL_NUMBER": "35083", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "39348", "NAME": "NUSTAR PERMIAN TRANSPORTATION AND STORAGE, LLC", "OPERATOR_STREET_ADDRESS": "8111 WESTCHESTER DRIVE", "OPERATOR_CITY_NAME": "DALLAS", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "75225", "LOCAL_DATETIME": "2/23/2021 10:55", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.27968", "LOCATION_LONGITUDE": "-101.88682", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "242", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "235", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "LOCAL OPERATING PERSONNEL, INCLUDING CONTRACTORS", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "OPERATOR EMPLOYEE", "INCIDENT_IDENTIFIED_DATETIME": "2/23/2021 10:55", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/23/2021 10:55", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "NO", "OSRO_OPERATOR_NOTIFIED_DT": "", "OSRO_ARRIVED_ON_SITE_DT": "", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "LENORAH", "ONSHORE_COUNTY_NAME": "MARTIN", "FEDERAL": "NO", "LOCATION_TYPE": "ORIGINATED ON OPERATOR-CONTROLLED PROPERTY, BUT THEN FLOWED OR MIGRATED OFF THE PROPERTY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "OTHER", "PIPE_TYPE": "", "JOINT_SUBTYPE": "", "ITEM_INVOLVED_DETAILS": "TANK", "PIPE_DIAMETER": "", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "0.01", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "YES", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "YES", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "431", "EST_COST_PROP_DAMAGE": "0", "EST_COST_EMERGENCY": "14527", "EST_COST_ENVIRONMENTAL": "3630", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "18588", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "INCORRECT OPERATION", "CAUSE_DETAILS": "TANK, VESSEL, OR SUMP/SEPARATOR ALLOWED OR CAUSED TO OVERFILL OR OVERFLOW", "PREPARER_NAME": "ALONSO RODRIGUEZ", "PREPARER_TITLE": "MANAGER PIPELINE SAFETY", "PREPARER_EMAIL": "alonso.rodriguez@nustarenergy.com", "PREPARER_TELEPHONE": "8063360712", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "JAMES ROBERTSON", "LOCAL_CONTACT_EMAIL": "james.robertson@nustarenergy.com", "LOCAL_CONTACT_TELEPHONE": "18063711304", "NARRATIVE": "A NUSTAR OPERATOR DISCOVERED A LEAK AT THE CQ TARZAN CDP. THE TANK AT THIS LOCATION HAD OVERFILLED AND RELEASED CRUDE OIL ONTO THE GROUND DUE TO LOSS OF COMMUNICATIONS.\ufffd\ufffd THE INVESTIGATION DETERMINED THAN AN EMPLOYEE DISABLED THE POWER TO THE SITE AS PART OF ADVERSE WEATHER PREPARATIONS.\ufffd\ufffdPRIOR TO STARTING THE SYSTEM BACK UP, THE NUSTAR EMPLOYEE FAILED TO RESTORE THE POWER TO THE PLC.\ufffd\ufffdTHE PLC AT THIS SITE IS EQUIPPED WITH A BATTERY BACKUP SYSTEM THAT ALLOWED THE PLC TO COMMUNICATE TEMPORARILY FOLLOWING START-UP. POST STARTUP, POWER TO THE PLC WAS LOST WHICH RESULTED IN LOSS OF COMMUNICATIONS TO THE CONTROL ROOM. THE SOIL REMEDIATION IS ONGOING. \ufffd"}
20210027Hazardous liquid (gravity / reporting-regulated)20212021-02-27 12:00:00PLAINS MARKETING, L.P.26085TXHOWARDFORSAN32.09855-101.41144003725.0NATURAL FORCE DAMAGECRUDE OILNONo data2026-08-31{"REPORT_RECEIVED_DATE": "3/29/2021", "IYEAR": "2021", "REPORT_NUMBER": "20210027", "SUPPLEMENTAL_NUMBER": "35098", "REPORT_TYPE": "ORIGINAL FINAL", "OPERATOR_ID": "26085", "NAME": "PLAINS MARKETING, L.P.", "OPERATOR_STREET_ADDRESS": "333 CLAY STREET, SUITE 1900", "OPERATOR_CITY_NAME": "HOUSTON", "OPERATOR_STATE_ABBREVIATION": "TX", "OPERATOR_POSTAL_CODE": "77002", "LOCAL_DATETIME": "2/27/2021 12:00", "TIME_ZONE": "CENTRAL", "DAYLIGHT_SAVINGS_IND": "NO", "LOCATION_LATITUDE": "32.09855", "LOCATION_LONGITUDE": "-101.41144", "COMMODITY_RELEASED_TYPE": "CRUDE OIL", "COMMODITY_SUBTYPE": "", "COMMODITY_DETAILS": "", "UNINTENTIONAL_RELEASE_BBLS": "0.4", "INTENTIONAL_RELEASE_BBLS": "", "RECOVERED_BBLS": "0.2", "FATALITY_IND": "NO", "NUM_EMP_FATALITIES": "", "NUM_CONTR_FATALITIES": "", "NUM_ER_FATALITIES": "", "NUM_WORKER_FATALITIES": "", "NUM_GP_FATALITIES": "", "FATAL": "0", "INJURY_IND": "NO", "NUM_EMP_INJURIES": "", "NUM_CONTR_INJURIES": "", "NUM_ER_INJURIES": "", "NUM_WORKER_INJURIES": "", "NUM_GP_INJURIES": "", "INJURE": "0", "ACCIDENT_IDENTIFIER": "AIR PATROL", "ACCIDENT_DETAILS": "", "OPERATOR_TYPE": "CONTRACTOR WORKING FOR THE OPERATOR", "INCIDENT_IDENTIFIED_DATETIME": "2/28/2021 12:06", "ON_OFF_SHORE": "ONSHORE", "COMMUNICATION_STATE_FED_IND": "NO", "PARTY_INITIATED_COMMUNICATION": "", "INITIAL_RESPONDER_COM_DATETIME": "", "ON_SITE_DATETIME": "2/28/2021 13:05", "NRC_RPT_DATETIME": "", "NRC_RPT_NUM": "NRC NOTIFICATION NOT REQUIRED", "ADDITIONAL_NRC_REPORT_NUMBERS": "", "IGNITE_IND": "NO", "IGNITE_DATETIME": "", "HOW_EXTINGUISHED": "", "HOW_EXTINGUISHED_OTHER_DETAIL": "", "PRODUCT_CONSUMED_BY_FIRE_BBLS": "", "EXPLODE_IND": "", "OIL_SPILL_RESP_PLAN_IND": "NO", "OSRO_MOBILIZED_IND": "YES", "OSRO_OPERATOR_NOTIFIED_DT": "2/28/2021 13:10", "OSRO_ARRIVED_ON_SITE_DT": "2/28/2021 14:25", "NUM_PUB_EVACUATED": "0", "ONSHORE_STATE_ABBREVIATION": "TX", "ONSHORE_CITY_NAME": "FORSAN", "ONSHORE_COUNTY_NAME": "HOWARD", "FEDERAL": "NO", "LOCATION_TYPE": "PIPELINE RIGHT-OF-WAY", "CROSSING": "NO", "BRIDGE_CROSSING_IND": "", "BRIDGE_TYPE": "", "RAILROAD_CROSSING_IND": "", "RAILROAD_TYPE": "", "ROAD_CROSSING_IND": "", "ROAD_TYPE": "", "WATER_CROSSING_IND": "", "WATER_TYPE": "", "WATER_NAME": "", "WATER_DEPTH": "", "WATER_SUBTYPE": "", "YEAR_RECENT_ENG_EVALUATION": "", "OFF_ACCIDENT_ORIGIN": "", "OFFSHORE_STATE_ABBREVIATION": "", "OFF_INSTATE_AREA": "", "OFF_INSTATE_BLOCK": "", "OFFSHORE_COUNTY_NAME": "", "OCS_TYPE": "", "OFF_OCS_AREA": "", "OFF_OCS_BLOCK": "", "ITEM_INVOLVED": "JOINT, INCLUDING HEAT-AFFECTED ZONE", "PIPE_TYPE": "", "JOINT_SUBTYPE": "PIPE GIRTH JOINT", "ITEM_INVOLVED_DETAILS": "", "PIPE_DIAMETER": "3", "MATERIAL_INVOLVED": "CARBON STEEL", "MATERIAL_DETAILS": "", "PERCENT_PIPE_SMYS": "2.5", "CLASSIFICATION_PIPELINE_SYSTEM": "REPORTING-REGULATED GATHERING", "WILDLIFE_IMPACT_IND": "NO", "FISH_AQUATIC_IMPACT_IND": "", "BIRDS_IMPACT_IND": "", "TERRESTRIAL_IMPACT_IND": "", "SOIL_CONTAMINATION": "YES", "LONG_TERM_ASSESSMENT": "NO", "REMEDIATION_IND": "NO", "SURFACE_WATER_REMED_IND": "", "GROUNDWATER_REMED_IND": "", "SOIL_REMED_IND": "", "VEGETATION_REMED_IND": "", "WILDLIFE_REMED_IND": "", "WATER_CONTAM_IND": "NO", "OCEAN_SEAWATER_IND": "", "SURFACE_CONTAM_IND": "", "GROUNDWATER_CONTAM_IND": "", "DRINKING_WATER_CONTAM_IND": "", "PRIVATE_WELL_CONTAM_IND": "", "PUBLIC_WATER_CONTAM_IND": "", "AMOUNT_RELEASED_BBLS": "", "REL_WATER_NAME": "", "EST_COST_OPER_PAID": "0", "EST_COST_GAS_RELEASED": "25", "EST_COST_PROP_DAMAGE": "2500", "EST_COST_EMERGENCY": "1200", "EST_COST_ENVIRONMENTAL": "0", "EST_COST_OTHER": "0", "EST_COST_OTHER_DETAILS": "", "PRPTY": "3725", "NUM_PERSONS_HOSP_NOT_OVNGHT": "0", "NUM_INJURED_TREATED_BY_EMT": "0", "NUM_RESIDENT_BUILDING_AFFCTD": "0", "NUM_BUSINESS_BUILDING_AFFCTD": "0", "CAUSE": "NATURAL FORCE DAMAGE", "CAUSE_DETAILS": "TEMPERATURE", "PREPARER_NAME": "NICOLAS GONZALEZ", "PREPARER_TITLE": "HSE COMPLIANCE SPECIALIST", "PREPARER_EMAIL": "nagonzalez@paalp.com", "PREPARER_TELEPHONE": "7136464376", "PREPARER_FAX": "", "LOCAL_CONTACT_NAME": "NICOLAS GONZALEZ", "LOCAL_CONTACT_EMAIL": "nagonzalez@paalp.com", "LOCAL_CONTACT_TELEPHONE": "7136464376", "NARRATIVE": "APPROXIMATELY 17 GALLONS OF CRUDE OIL WERE RELEASED FROM THE SETTLES WEST 3\" INCH PIPELINE. THE DATE AND TIME OF THE RELEASE (PART A Q4) IS INDICATIVE OF THE EARLIEST POSSIBLE TIME THE RELEASE COULD HAVE STARTED, AS IT WAS THE LAST TIME THE SEGMENT HAD BEEN INSPECTED. THE CAUSE OF THE RELEASE FROM THE PIPE-GIRTH JOINT WAS ATTRIBUTED TO NATURAL FORCE DAMAGE AS A RESULT OF COLD TEMPERATURES. TO PREVENT FUTURE RELEASES, PLAINS REPLACED THIS SECTION OF PIPE WITH NEW WELDS AND FITTINGS, AND ADDED COATING."}

Need the whole thing? Spreadsheet links, downloads, and AI access come with Level 3.

See pricing